Perbandingan Hasil Pemeriksaan Jumlah Eritrosit Dengan Teknik Homogenisasi Sekunder Empat Kali Dan Delapan Kali
DOI:
https://doi.org/10.32524/jksp.v6i2.989Kata Kunci:
Inversion technique, Erythrocyte countAbstrak
Red blood cell counts are mostly laboratory tests. The pre-analysis step is subject to errors, especially homogenization. The homogenization technique used in the lab is the inversion technique. According to CLSI and BD Vacutainer, homogenizing is achieved by inverting the tube 8-10 times and by PerMenKes No. 43 up to 10-12 times. The EDTA blood is stored in the tube, if it is allowed to stand, a deposition process will occur, namely rouleaux, sedimentation, and compaction so that the results of the examination obtained are incorrect. Secondary homogenization is performed to ensure correct examination results. The purpose of this study is to determine if there is a difference in red blood cells in the secondary homogenized blood using inversion techniques four and eight times. The research was pre-experimental, with a Static group comparison design. The K2EDTA blood was 30 samples, which were secondarily homogenized by inversion technique 4 times and 8 times, after being allowed to be held for 30 minutes. Data analysis using Wicoxon test. The probability value of the Wilcoxon test was 0.000 <0.05. These results show that there are differences in erythrocyte count in the secondary homogenized blood 4 times and 8 times. Factors that may cause differences are imperfect deposit and homogenization. When blood is allowed to stand, there is a deposition process, which involves 3 steps, namely, rouleaux, sedimentation, and compaction, erythrocytes are at the bottom of the tube. Secondary homogenization 4 times, is not sufficient to completely homogenize, thus affecting the results of the red blood cell count examination. There are differences in red blood count in homogenized secondary blood 4 times and 8 times
Referensi
Ashenden, M. (2012). Preanalytical mixing of whole-blood specimens in the context of the Athlete Passport. https://pubmed.ncbi.nlm.nih.gov/22049219/
BD Vacutainer. (2010). Order of Draw for Multiple Tube Collection. Vol. 23 No. 32, 8. 10.
Jain, A. et al. (2018). Storage stability of commonly used haematological parameters at 33 °c. Biochemia Medica. Biochemia Medica, Editorial Office, 28(2 Special Issue). doi: 10.11613/BM.2018.020901.
CLSI. GP41-A6. (2017). Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard-Sixth Edition From Clinical and Laboratory Standards Institute.
Elfiansyah & Hutabarat. (2017). Pengaruh Modifikasi Timer Pada Pengendali Roller Mixer. Jurnal Mutiara Elektromedik, November.
Jemani, & Kurniawan, M. R. (2019). Analisa Quality Control Hematologi di Laboratorium Rumah Sakit An-Nisa Tangerang. Binawan Student Journal, 1(2).
Jitowiyono, S. (2018). Asuhan Keperawatan Pada Pasien Dengan Gangguan Sistem Hematologi. Yogyakarta: Pustaka Baru Press.
Kiswari, R. (2014). Hematologi dan Transfusi. Jakarta: Penerbit Erlangga
Lieseke, CL., & Zeibig, EA. (2018). Buku Ajar Laboratorium Klinis. Jakarta : EGC
Lippi, G., Gian, LS., Martina, M., Giusppe, B., Gian, CG. (2007). Evaluation of Different Mixing Procedures for K2EDTA Primary Samples on Hematologi Testing
Nugraha, G. (2017). Panduan Pemeriksaan Laboratroium Hematologi dasar (edisi 2). Jakarta: CV. Trans Info Media
Oliveira, Gabriel Lima et al. (2014). Processing of Diagnostic Blood Specimens: is it Really Narayanan, S. (2005). Preanalytical issues related to blood sample mixing https://acutecaretesting.org/en/articles/preanalytical-issues-related-to-blood-sample-m
Necessary to Mix Primary Blood Tubes after Collection with Evacuated Tube System. Volume 12, Nomor 1
Peraturan Menteri Kesehatan Republik Indonesia. (2013). Cara Penyelanggaraan Laboratorium Klinik yang Baik
Riswanto. (2013). Pemeriksaan Laboratorium Hematologi. Alfamedia & Kanal Medika
Saryono. (2017). Metodologi Penelitian Kesehatan. Yogyakarta: Mitra Cendikia Press
Westgard CLIA. (2019). Requirements for Analytical Quality. https://www.westgard.com/clia.htm
Siregar, M. T., Sriwulan, W., Setiawan, D., & Nuryati, A. (2018). Kendali Mutu. Kementerian Kesehatan Republik Indonesia
Yucel, C., Turhan, T., & Calci, E. (2017). The effect of preanalytical mechanical mixing time on complete blood cell count parameters in the emergency laboratory. Medicine Science | International Medical Journal, December, 1. https://doi.org/10.5455/medscience.2016.05.8552
##submission.downloads##
Diterbitkan
Cara Mengutip
Terbitan
Bagian
Lisensi
Hak Cipta (c) 2023 Jurnal Kesehatan Saelmakers PERDANA (JKSP)
Artikel ini berlisensiCreative Commons Attribution-ShareAlike 4.0 International License.